In certain areas of the United States, building codes do not allow for a continuous slot to be cut into the roof structure. This is especially true on the west coast and other earthquake prone areas. Roll Vent can be installed on a roof without a continuous slot.

Drill 1 1/4" holes every 2" on center (this will leave 3/4" of deck between each hole) and 1-1/4" on center from the peak of the roof. From each gable end, leave 6" with no holes cut.

This installation will work with/without the presence of a 2X ridge beam.

Roll Vent will vent 6.1 sq. in. per linear foot in this application.

 

 

 

 